+

0-5V 0-10V 4-20MA Load Cell sensor Amplifier Weighing Transmitter voltage current converter Working voltage: DC 12-24V

USD 11.49

0-5V 0-10V 4-20MA Load Cell sensor Amplifier Weighing Transmitter voltage current converter Working voltage: DC 12-24V

Description

start

Low Noise LNA 0.05-4G NF=0.6dB Wideband Amplifier ... US $16.36
FM band 76-108MHz bandpass filter (BPF) 100W SSB C... US $36.26
4.2V Charger + 5V Discharger Board DC DC Converter... US $3.89
0.56" PT100 Digital LED Thermometer -200~450C Temp... US $9.85
I2S HiFi DAC ES9023 Expansion Board Decode Board E... US $19.33
Digital display LED dc 12v Bluetooth mp3 decoder b... US $10.22
3s 4s 12V lithium battery capacity Tester display ... US $2.13
AD8310 Fast Voltage-Out DC-440MHz 90dB Logarithmi... US $12.08
dc 12V Light Control Switch Controller Laser Recei... US $6.83
20-3000MHz 35dB Low Noise Broadband Radio frequenc... US $14.87

end

 

 

aeProduct.getSubject()

 

 
 
Description:
  • Features: Housing and wire connectors are waterproof design, good sealing, suitable for harsh environments Look beautiful, durable, anti-jamming performance Ultra- high-precision op amp circuit, high accuracy, good stability The power supply has reverse polarity protection, surge protection, overcurrent protection Suitable for weighing, pull pressure, torque, and other strain sensor. Technical Parameters Working voltage: DC 12-24V Output signal: voltage (0-5V, 0-10V, 1-5V, ± 5V) 4-20ma input signal:sensor sensitivity 2.0MV/V output incentive:5V(E+) Operating temperature range: -20 - 80 Operating Humidity: 10% RH-90% RH (non-condensing) Accuracy: better than 0.1% F.S Precision is better than 0.05% F.S Gear selection:dial switch turn OFF , V0 output 0-5v , 1 turn to ON V0 output 0-10V 1 and 2 both turn to OFF VO output 0-5v IO output 4-20MA About debugging: 1 zero adjustment First of all, make the system is in the idle state, adjust the marking "ZERO" potentiometer to adjust the zero offset. The multimeter is used to measure the output voltage or current, let show a value as close as possible to the zero value display. Or change the magnification zero change will become big. 2 gain adjustment The system loading a certain weight value (the recommended range: 80% ~ 100% FS), the calculation of the output current value according to the load weight and the maximum weighting value relation, using the digital multimeter monitoring output, potentiometer to adjust amplifier gain spin labeled "SPAN". 3 the retest The system is in the idle state, measuring the zero output; loading a certain weight value, output voltage measurement whether fluoride expectation magnification If not, repeat steps 1, 2 adjust again.    
  • Package Contents 100% Brand New 1 x 0-10V / 4-20mA Load Cell sensor Amplifier Board  
 

 

Specification

Brand Name : NoEnName_Null

is_customized : Yes

Operating Temperature : standard

Application : Other

Model Number : new

Dissipation Power : w

Supply Voltage : v

Type : Voltage Regulator

Usage : Laptop

Condition : New

1PCS CA3260AE CA3260 DIP8 BY
USD 0.47USD 0.50
+