+

DC 5V/AC 100-250V 2 Channel 4 Channel 30A High and Low Level Trigger Control Relay Module with Isolation Relay Switch Board

USD 4.53USD 6.12

DC 5V/AC 100-250V 2 Channel 4 Channel 30A High and Low Level Trigger Control Relay Module with Isolation Relay Switch Board

Description

Description 37

DC 5V/AC 100-250V 2 Channel 4 Channel 30A High and Low Level Trigger Control Relay Module with Isolation Relay Switch Board 

2 Channel Relay Module
 
Feature:
 
This is a high-low level trigger 2-channel relay module that can control two loads.
Large load capacity, the relay can connect to maximum 30A, 250V loads.
Easy to use, designed with screw terminals for convenient connection.
High or low level trigger can be selected by jumper.
Four mounting holes are great for installation.
 
Description:
 
Power Supply: AC100-250V
Input Control Signal Voltage: 0-1V DC(low state relay), 1.5-5V DC(high state relay)
Working Current: 378mA
Load Capacity: 30A, 250V AC/ 30V DC
Trigger Input: 
DC +: 5V
DC -: GND
CH1: Signal trigger terminal
CH2: Signal trigger terminal
 
4 Channel Relay Module
 
Product introduction:
 
1. Relay 250V 30A
2. Size: 143*60*20 (length*width*height)
3. Input power: 5V DC (optional isolation module, AC100-250V power supply)
4. Input high level control signal voltage:
(0-1V state low level relay OFF)
(1.5-5V state high level relay ON)
 
Input part:
 
DC+: Connect to the positive pole of the power supply (power supply according to the relay voltage, if an isolation module is selected, this interface can be used for high-level trigger power supply)
DC-: Connect the negative pole of the power supply
CH1: 1 way relay module signal trigger terminal (high and low level trigger is valid (optional))
CH2: 2-way relay module signal trigger terminal (high and low level trigger is valid (optional))
CH3: 3-way relay module signal trigger terminal (high and low level trigger is valid (optional))
CH4: 4-way relay module signal trigger terminal (high and low level trigger is valid (optional))
 
Meaning of high level and low level:
 
High-level triggering refers to the fact that there is a positive voltage between the signal trigger terminal (IN) and the negative pole of the power supply. It is usually a trigger method that connects the positive pole of the power supply to the trigger terminal. When the trigger terminal has a positive voltage or reaches the trigger When the voltage is applied, the relay is closed.
Low-level triggering refers to when the voltage between the signal trigger terminal and the negative pole of the power supply is OV, or the voltage at the trigger terminal is lower than the voltage of the positive pole of the power supply. When the voltage is low enough to trigger, the relay will be closed. A trigger mode in which the negative pole of the power supply is connected to the trigger terminal, so that the relay is closed.
 
Reference electrical parameters (if there are changes, please refer to the actual product):
 
1 channel :
 
Voltage version: 5V
Quiescent current: 0mA 
Operating current: 188mA 
Trigger voltage: 1.5-5V 
Trigger current: 2mA
 
2 channels:
 
Voltage version: 5V
Quiescent current: 0mA 
Operating current: 378mA 
Trigger voltage: 1.5-5V 
Trigger current: 2mA
 
4 channels:
 
Voltage version: 5V
Quiescent current: 0mA 
Operating current: 760mA 
Trigger voltage: 1.5-5V 
Trigger current: 2mA
picture 37
Specification

Brand Name : diymore

Supply Voltage : DC 5V/AC 100-250V

Type : Voltage Regulator

is_customized : Yes

Model Number : DC 5V/AC 100-250V Relay Module

Package : TQFP

Application : Computer

Origin : CN(Origin)

Condition : New

10PCS BF245A BF245 TO 92
USD 1.50USD 1.72
+