Digital display can mobilize power/cycle/high and low level trigger multifunctional delay 12V Relay module

USD 4.75USD 5.00

Digital display can mobilize power/cycle/high and low level trigger multifunctional delay 12V Relay module

Description

Digital display adjustable set power / cycle / high and low trigger multi-function delay 12V relay module

1. Product introduction:
This product set power-on trigger delay, cycle timing delay, high and low level trigger delay and self-locking, point trigger in one, with digital display timing relay module, with accurate delay, 18 kinds of functions are optional, the maximum can be Connected to 220V 10A AC or 30A 10A DC load, widely used in smart home, automatic control, product life test, electronic enthusiast design applications, etc. The product has 5V.12V.24V three voltage versions available, delay time 1-999 seconds and 1-999 minutes to choose, you can choose the appropriate voltage version according to your needs.
2. Function introduction:
This product has 18 function options, the specific functions are as follows:Power-on (power-on) delay function part:
Function 1 (timed off): The relay is closed when power is on, and the relay is disconnected after the delay time is over (the power will remain disconnected all the time), and the time is between 1 second and 999 seconds (or 1-999 minutes). Tune, if re-powered or a trigger signal to the IN interface (support high/low level trigger, external switch button trigger), interrupt and repeat the above functions;Function 2 (timed pull-in): The relay is disconnected at power-on, the relay is closed after the delay time is over (the power will remain closed for a long time), and the time is between 1 second and 999 seconds (or 1-999 minutes). Tune, if re-powered or a trigger signal to the IN interface (support high/low level trigger, external switch button trigger), interrupt and repeat the above functions;Function 3 (timed pull and then disconnect): the relay is closed when power is on, the pull-in time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is broken after the end of the pull-in delay. On, off time (T2) is adjustable from 1 second to 999 seconds (or 1-999 minutes). After the off delay is over, the relay will remain closed, such as powering up again or giving a trigger signal to the IN interface. (Support high/low level trigger, external switch button trigger), interrupt and repeat the above functions;Function 4 (Timed Disconnect and Retract): The relay is disconnected at power-on, and the off time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes). After the disconnection delay is over, the relay is sucked. The pull-in time (T2) is adjustable from 1 second to 999 seconds (or 1-999 minutes). The relay will remain open after the pull-in delay expires, such as re-powering or giving a trigger signal to the IN interface. (Support high/low level trigger, external switch button trigger), interrupt and repeat the above functions;Loop timing function part:Function 5 (infinite loop timing mode 1): After power-on, the relay is closed, the pull-in time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is disconnected after the pull-in delay ends. The disconnection time (T2) is adjustable between 1 second and 999 seconds (or 1-999 minutes). After the disconnection delay is over, the relay is again pressed by the T1 time to infinitely cycle. For example, power on again or give The IN interface has a trigger signal (supporting high/low level triggering, external switch button triggering), which can interrupt and repeat the above functions;Function 6 (infinite loop timing mode 2): The relay is disconnected after power-on, the off time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is closed after the off delay is over. The pull-in time (T2) is adjustable between 1 second and 999 seconds (or 1-999 minutes). After the pull-in delay is over, the relay is again turned off by the T1 time, thereby infinitely cycling. The IN interface has a trigger signal (supporting high/low level triggering, external switch button triggering), which can interrupt and repeat the above functions;Function 7 (Limited Cycle Timing Mode 1): The relay is energized after power-on, the pull-in time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is disconnected after the pull-in delay ends. The off time (T2) is adjustable between 1 second and 999 seconds (or 1-999 minutes). After the off delay is over, the relay is again pressed by the T1 time, and the number of cycles can be set from 1 to 999. If the power is turned back on or a trigger signal is sent to the IN interface (supporting high/low level triggering, external switch button triggering), the above functions can be interrupted and repeated once;Function 8 (limited cycle timing mode 2): The relay is disconnected after power-on, the off time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), and the relay is closed after the end of the off delay. The suction time (T2) is adjustable between 1 second and 999 seconds (or 1-999 minutes). After the suction delay is over, the relay is again turned off by the T1 time, and the number of cycles can be set from 1 to 999 times. If the power is turned back on or a trigger signal is sent to the IN interface (supporting high/low level triggering, external switch button triggering), the above functions can be interrupted and repeated once;Trigger delay function part:Function 9 (trigger timing off 1): After power-on, the relay does not move in the off state, waiting for the IN interface trigger signal (supports high/low level trigger, external switch button trigger), when there is a trigger signal, the relay sucks In combination, the suction time is adjustable between 1 second and 999 seconds (or 1-999 minutes). The delay ends and the relay is disconnected, waiting for the next trigger signal. The IN interface trigger is invalid during the delay.Function 10 (trigger timing pull-in 1): After power-on, the relay does not operate in the off state, waiting for the IN interface trigger signal (supports high/low level trigger, external switch button trigger), when there is a trigger signal, the relay remains Disconnected state and delayed, the disconnection time is adjustable between 1 second and 999 seconds (or 1-999 minutes), the delay is over, the relay is closed (the power will remain stuck all the time), waiting for the next trigger signal The IN interface trigger is invalid during the delay.Function 11 (trigger timing off 2): After power-on, the relay does not move in the off state, waiting for the IN interface trigger signal (supports high/low level trigger, external switch button trigger), when there is a trigger signal, the relay sucks The pull-in time is adjustable between 1 second and 999 seconds (or 1-999 minutes). The delay ends and the relay is disconnected, waiting for the next trigger signal. The IN interface trigger is valid during the delay.Function 12 (trigger timing pull-in 2): After power-on, the relay does not move in the off state, waiting for the IN interface trigger signal (supporting high/low level trigger, external switch button trigger), when there is a trigger signal, the relay remains Disconnected state and delayed, the disconnection time is adjustable between 1 second and 999 seconds (or 1-999 minutes), the delay is over, the relay is closed (the power will remain stuck all the time), waiting for the next trigger signal The IN interface trigger is valid during the delay.Function 13 (trigger timing disconnect and re-sink 1): After power-on, the relay does not move in the off state, waiting for the IN interface trigger signal (support high/low level trigger, external switch button trigger), when there is a trigger signal , the relay remains off and delayed, the off time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), the relay is closed after the disconnection delay, and the pull-in time (T2) ) Adjustable between 1 second - 999 seconds (or 1-999 minutes), the relay will remain disconnected after the end of the pull-in delay. Wait for the next trigger signal, the IN interface trigger is invalid during the delay.Function 14 (trigger timing pull-in and then disconnect 1): After power-on, the relay does not move in the off state, waiting for the IN interface trigger signal (supports high/low level trigger, external switch button trigger), when there is a trigger signal ,; relay suction combined delay, pull-in time (T1) adjustable between 1 second - 999 seconds (or 1-999 minutes), after the end of the pull-in delay, the relay is disconnected, the off time (T2) is 1 The second-999 seconds (or 1-999 minutes) can be adjusted. After the off-delay is over, the relay will remain closed. Wait for the next trigger signal. The IN interface trigger is invalid during the delay.Function 15 (trigger timing disconnect and re-sink 2): After power-on, the relay does not move in the off state, waiting for the IN interface trigger signal (support high/low level trigger, external switch button trigger), when there is a trigger signal , the relay remains off and delayed, the off time (T1) is adjustable between 1 second and 999 seconds (or 1-999 minutes), the relay is closed after the disconnection delay, and the pull-in time (T2) ) Adjustable between 1 second and 999 seconds (or 1-999 minutes), the relay will remain disconnected after the end of the pull-in delay. Wait for the next trigger signal, the IN interface trigger is valid during the delay.Function 16 (trigger timing pull-in and then disconnect 2): After power-on, the relay does not move in the open state, waiting for the IN interface trigger signal (support high/low level trigger, external switch button trigger), when there is a trigger signal ,; relay suction combined delay, pull-in time (T1) adjustable between 1 second - 999 seconds (or 1-999 minutes), after the end of the pull-in delay, the relay is disconnected, the off time (T2) is 1 The second-999 seconds (or 1-999 minutes) can be adjusted. After the off-delay is over, the relay will remain closed. Wait for the next trigger signal. The IN interface trigger is valid during the delay.Function 17 (self-locking relay function): When the IN interface has a trigger signal (support high/low level trigger, external switch button trigger), the relay pulls in, then gives a signal, the relay is disconnected, press 8 Sel key Simulation test function.Function 18: (trigger relay function): When the IN interface has a trigger signal (support high/low level trigger, external switch button trigger), the relay pulls in, the signal disappears, and the relay is disconnected.
Third, the product use method:
1. The product is connected to the corresponding DC voltage at the DC voltage terminal according to the voltage version. Do not connect the wrong power supply or connect the reverse power supply, otherwise the module may be burned out;2. Set the product function first, select with FS button, select function from 1-18, such as the above function arrangement;3. After selecting the function, double-click the FS button, it will display t, then adjust the time. Use 8 Sel button and 0-9 Sel button to adjust the time. 8 Sel button is to choose which 8 word to adjust, 0-9 Sel is The selected 8 word adjustment value will be selected;4. If there is double time adjustment, after selecting the function, double click the FS button, it will display t1, then double click will display t2, then use 8 Sel button and 0-9 Sel button to adjust the time, cycle timing, Then double-clicking will have n words representing the number of times the test needs to be set, and the number of times is adjusted with the 8 Sel button and the 0-9 Sel button.5. Delay time 1-999 seconds and 1-999 minutes can be automatically switched by long pressing the FS button, the display A represents a time range of 1-999 seconds, and the display b represents a time range of 1-999 minutes;6. Functions 17 and 18 do not need to adjust the time. For these two functions, the trigger interface directly controls the relay when there is a trigger signal;7. Trigger selection: When the middle of the jumper is connected with the L terminal, it is a low level trigger. At this time, a button switch is connected between the IN terminal and the DC terminal. It can also be used as a trigger switch. When the jumper is connected with the H terminal. It is a high level trigger. At this time, the IN terminal and the DC+ terminal are connected to a push button switch, which can also be used as a trigger switch.8. Press and hold the button 8 Sel for three seconds to turn off the display of the digital tube. Press and hold for 3 seconds in the off state. 8 Sel can turn on the display of the digital tube;
Four. Product parameters:
  1. Dimensions: 63.5mm (L) * 38.5mm (W) * 18.5mm (H)    2. Positioning hole size: 58.5mm*33.5mm Hole diameter: 3.1mm    3. Relay load capacity: 220V 10A AC or 30V 10A DC    4.12V quiescent current: 43mA maximum power consumption: 90mA
Specification

Brand Name : YUFO-IC

Supply Voltage : datasheet

Type : Other

is_customized : Yes

Model Number : title & photo

Dissipation Power : datasheet

Operating Temperature : datasheet

Origin : CN(Origin)

Application : Other

Condition : New

Package : Other

Application : DIY

MRF185 MOSFET
USD 22.00
10PCS LF347N LF347 DIP-14
USD 1.28USD 1.47
+