Free Ship 3pcs All the Way to the Relay Module Delay Power Disconnect Trigger Delay Cycle Timing Circuit Switch XY-LJ02

USD 17.36USD 18.27

Free Ship 3pcs All the Way to the Relay Module Delay Power Disconnect Trigger Delay Cycle Timing Circuit Switch XY-LJ02

Description

One-way relay module delay power failure disconnect trigger delay cycle timing circuit switch

0.01 seconds (minimum)~ 9999 minutes (maximum) continuously adjustable

the liquid crystal display of this product is very clear, simple and easy to use, and has powerful functions, but please take a look at the operation instructions of this product in detail, which is a very practical product.

Module highlights:

1. With liquid crystal display, the current mode and parameters are clear at a glance, very clear, simple and practical;

2. Support high and low level triggering, switch value control, suitable for most occasions;

3. Wide voltage power supply (6~30V) supports micro USB 5.0V power supply, very convenient to use;

4. Supports uploading and setting parameters of UART data;

5. There is one-button emergency STOP function (STOP button), with reverse connection protection, reverse connection does not burn;

6. The sleep mode is added, after it is enabled, there is no operation within 5 minutes, and the LCD backlight is automatically turned off; Any button is used to wake up;

7. Different OP, CL and LOP can be set parameters, these parameters are independent of each other and are saved separately;

8. All set parameters are automatically saved after power failure.

 

Mode of operation:

P1 : when the signal is triggered, the relay will break over OP time, and then disconnect; In OP time, signal triggered again invalid

 

P2:  when the signal is triggered, the relay will break over OP time, and then disconnect; In OP time, signal triggered again re-timing   

P3 : when the signal is triggered, the relay will break over OP time, and then disconnect; In OP time, signal triggered again reset, relay off, stop timing

P4 : give trigger signal, relay disconnect CL after the time, the relay break over OP time, after the timing is completed, disconnect the relay;

P5 : give trigger signal, relay break over OP after the time, the relay is disconnected CL time, then cycle the above actions, give signals again in the cycle, switch off the relay, stop timing; Cycle times ( LOP) may be provided;

P6 : no trigger signal is needed after power-on, relay break over OP time relay is turned off CL time, cycle the above actions; Cycle times ( LOP) may be provided;

P7 : signal maintenance function if there is a trigger signal, the timing is reset, and the relay remains break over; When the signal disappears, the timing OP after disconnecting the relay; During the timing period, there will be another signal, and the timing will be reset;

 

product parameters:

1: working voltage:6-30V support micro USB 5.0V power supply

2: trigger signal source: high level trigger (0.2V ~ 24V), low level trigger (V ~ V), switch value control (passive switch).

3: output capacity: DC can be controlled30v5A within or exchange220v5A within the device

4 as these are: Static current:15mA  working current:50mA

5: Service life: greater10 ten thousand times; Working temperature:-40-85℃; Size: 8.0*3.8*1.9cm

6: with optical coupling isolation, enhance anti-interference ability, industrial level circuit board, set parameters will always be remembered after power failure.

Time range

0.01 seconds (minimum)~ 9999 minutes (maximum) continuously adjustable

how to select the timing range:

on the OP/CL parameter modification interface, briefly press the STOP key, select the timing range;

XXXX no XIAOSHUDIAN, timing range1 seconds~ 9999 seconds

XXX.X  XIAOSHUDIAN is in ten digits, timing range0.1 seconds~ 999.9 seconds

XX.XX  XIAOSHUDIAN in 100 digits, timing range0.01 seconds~ 99.99 seconds

X.X.X.X  fully bright XIAOSHUDIAN, timing range1-9999 minutes

for example, if you want to set OP3.2 seconds, then move the XIAOSHUDIAN to the ten, LCD 003.2

for more information about these parameters: OP break over time, CL the off-time, LOP  the number of cycles (1-9999 times,"----" on behalf of the infinite subcycle)

 

a, how to reconfigure parameters for an RDS

a)    through long press SET key to enter the setting interface;

b)    first set the working mode, the working mode flickers to remind, by short Press UP/DOWN key to set the working mode;

c)    short Press SET key, select the working mode, and enter the system parameter setting;

d)   on the system parameter setting interface, short Press SET key to switch the system parameters to be modified, short Press/ long press UP/DOWN key modify;

( note: in P-1 ~ p-3 , P-7 mode a short press SET invalid);

e)    in OP/CL parameter modification interface, short Press STOP the switching timing unit(1s/0.1s/0.01s/1min) ;

f)    all parameters are set, long Press SET key, save the parameter settings and exit the settings interface;

 1.     Remote Data upload and parameter settings:

system support UART  data upload and parameter setting function (TTL level);

 

UART:9600,8,1

command

function

read

reading System parameters

OP:xxxx

OP:xxx.x

OP:xx.xx

OP:x.x.x.x

1s

0.1s

0.01s

1 min

CL:xxxx

CL:xxx.x

CL:xx.xx

CL:x.x.x.x

1s

0.1s

0.01s

1 min

LP:xxxx

the number of cycles

on

open the relay function

off

turns off the relay function

PX

probe into the setup of the model P1, P2 etc.

 

   Additional features

a)   automatic sleep function: on the running interface, through long press STOP key to start or disable the automatic sleep function ( L-P select on then the sleep function is started, off turn off the sleep function);

b)   relay function selection: on the operation interface, press short STOP key, start or close relay function,'on'  meet break over conditions relay normal break over,'OFF'  the relay meets the break over condition and does not break over; 'OFF' in the state, the system flickers 'OUT ';

c)   parameter view: on the running interface, short Press SET key to display the current parameter settings of the system, which does not affect the normal operation of the system;

 

d)   display Content Switching: in P-5 P-6 in the mode, by short Press DOWN key, switch the display content( run time/ the number of cycles);

 

 

Specification

Brand Name : YUFO-IC

Supply Voltage : Datasheet

Model Number : Photo & Title

Package : Datasheet

Application : Datasheet

Dissipation Power : Datasheet

Operating Temperature : Datasheet

Condition : New

is_customized : Yes

Type : Other

Product Type : Hot Sale

The Origin : Mainland China

Power Mode : Direct Current (DC)

Voltage : ≤ 36V (Included)

Brand : Datasheet

Model : XY-LJ02

STA323W STA323 HSSOP36 5PCS
USD 3.15USD 3.80
MT6592V-X BGA New Original
USD 6.25USD 12.50
GL823 ssop24 10pcs
USD 17.20USD 20.00
+