MQ-131 MQ131 Ozone Sensor Oxygen Sensor Gas Sensor Module For Ozone Concentration Exceeded Alarm 10ppm-1000ppm Output MQ 131
Product Type : Semiconductor Gas Sensor
Standard package: bakelite, metal cover
Detection gas: ozone
Detection concentration: 10~1000ppm ozone
Loop voltage Vc: ≤24V DC
Heating voltage VH : 5.0V ± 0.1V AC or DC
Load resistance RL: adjustable
Heating resistance RH : 31 Ω ± 5 Ω (room temperature)
Heating power consumption PH: ≤900mW
Sensitivity S : Rs (in 200ppm O3) / Rs (in air) ≥ 2
Output voltage △Vs : ≥1.0V (in 200ppm O3)
Concentration slope α : ≤ 0.6 ( R10ppm / R100ppm O3)
Temperature, humidity: 20 °C ± 2 °C; 55% ± 5% RH
Standard test circuit: Vc: 5.0V ± 0.1V; VH: 5.0V ± 0.1V
Warm-up time: no less than 48 hours
Oxygen content: 21% (not less than 18%, (oxygen concentration will affect the initial value, sensitivity and repeatability of the sensor, please consult when using at low oxygen concentration)
Life expectancy: 5 years
Note: The figure above shows the basic test circuit for the MQ131 sensor. The sensor requires two voltages to be applied: heater voltage (VH) and test voltage (VC). The VH is used to provide a specific operating temperature for the sensor, either DC or AC. The VRL is the voltage across the load resistor (RL) of the sensor in series. VC is the voltage for testing the load resistor RL and requires a DC power supply.
Brand Name : EC Buying
is_customized : Yes
Theory : Current Sensor
Usage : Gas Sensor
Model Number : MQ131 Ozone Sensor
Material : Mixture
Type : Gas Sensor
Origin : Mainland China
Output : Analog Sensor