PZEM-004 AC Digital Multifunction Watt Power Volt Amp Current Test Meter Module For Arduino Ammeter Voltmeter 0-100A 80-260V

USD 4.80USD 6.16

PZEM-004 AC Digital Multifunction Watt Power Volt Amp Current Test Meter Module For Arduino Ammeter Voltmeter 0-100A 80-260V

Description

Multifunction AC Digital Meter 0-100A 80-260V Watt Power Volt Amp Current Test Module PZEM-004T For Arduino TTL COM2\COM3\COM4

Overview
This document describes the specification of the PZEM-004T AC communication module,
the module is mainly used for measuring AC voltage, current, active power, frequency, power
factor and active energy, the module is without display function, the data is read through the TTL
interface.
PZEM-004T-10A: Measuring Range 10A (Built-in Shunt)
PZEM-004T-100A: Measuring Range 100A (external transformer)
1.Function description
1.1 Voltage
1.1.1 Measuring range:80~260V
1.1.2 Resolution: 0.1V
1.1.3 Measurement accuracy: 0.5%
1.2 Current
1.2.1 Measuring range: 0~10A(PZEM-004T-10A); 0~100A(PZEM-004T-100A)
1.2.2 Starting measure current: 0.01A(PZEM-004T-10A); 0.02A(PZEM-004T-100A)
1.2.3 Resolution: 0.001A
1.2.4 Measurement accuracy: 0.5%
1.3 Active power
1.3.1 Measuring range: 0~2.3kW(PZEM-004T-10A); 0~23kW(PZEM-004T-100A)
1.3.2 Starting measure power: 0.4W
1.3.3 Resolution: 0.1W
1.3.4 Display format:
<1000W, it display one decimal, such as: 999.9W
≥1000W, it display only integer, such as: 1000W
1.3.5 Measurement accuracy: 0.5%
1.4 Power factor
1.4.1 Measuring range: 0.00~1.00
1.4.2 Resolution: 0.01
1.4.3 Measurement accuracy: 1%
1.5 Frequency
1.5.1 Measuring range: 45Hz~65Hz
1.5.2 Resolution: 0.1Hz
1.5.3 Measurement accuracy: 0.5%
1.6 Active energy
1.6.1 Measuring range: 0~9999.99kWh
1.6.2 Resolution: 1Wh
1.6.3 Measurement accuracy: 0.5%
1.6.4 Display format:
<10kWh, the display unit is Wh(1kWh=1000Wh), such as: 9999Wh
≥10kWh, the display unit is kWh, such as: 9999.99kWh
1.6.5 Reset energy: use software to reset.
1.7 Over power alarm
Active power threshold can be set, when the measured active power exceeds the threshold, it
can alarm
1.8 Communication interface
RS485 interface。
2 Communication protocol
2.1 Physical layer protocol
Physical layer use UART to RS485 communication interface
Baud rate is 9600, 8 data bits, 1 stop bit, no parity
2.2 Application layer protocol
The application layer use the Modbus-RTU protocol to communicate. At present, it only
supports function codes such as 0x03 (Read Holding Register), 0x04 (Read Input Register), 0x06
(Write Single Register), 0x41 (Calibration), 0x42 (Reset energy).etc.
0x41 function code is only for internal use (address can be only 0xF8), used for factory
calibration and return to factory maintenance occasions, after the function code to increase 16-bit
password, the default password is 0x3721
The address range of the slave is 0x01 ~ 0xF7. The address 0x00 is used as the broadcast
address, the slave does not need to reply the master. The address 0xF8 is used as the general
address, this address can be only used in single-slave environment and can be used for calibration
etc.operation.
2.3 Read the measurement result
The command format of the master reads the measurement result is(total of 8 bytes):
Slave Address + 0x04 + Register Address High Byte + Register Address Low Byte + Number
of Registers High Byte + Number of Registers Low Byte + CRC Check High Byte + CRC Check
Low Byte.
The command format of the reply from the slave is divided into two kinds:
Correct Reply: Slave Address + 0x04 + Number of Bytes + Register 1 Data High Byte +
Register 1 Data Low Byte + ... + CRC Check High Byte + CRC Check Low Byte
Error Reply: Slave address + 0x84 + Abnormal code + CRC check high byte + CRC check
low byte
Abnormal code analyzed as following (the same below)
⚫ 0x01,Illegal function
⚫ 0x02,Illegal address
⚫ 0x03,Illegal data
⚫ 0x04,Slave error
The register of the measurement results is arranged as the following table
For example, the master sends the following command (CRC check code is replaced by
0xHH and 0xLL, the same below)
0x01 + 0x04 + 0x00 + 0x00 + 0x00 + 0x0A + 0xHH + 0xLL
Indicates that the master needs to read 10 registers with slave address 0x01 and the start
address of the register is 0x0000
The correct reply from the slave is as following:
0x01 + 0x04 + 0x14 + 0x08 + 0x98 + 0x03 + 0xE8+0x00 + 0x00 +0x08 + 0x98+ 0x00 +
0x00 + 0x00 + 0x00 + 0x00 + 0x00 + 0x01 + 0xF4 + 0x00 + 0x64 + 0x00 + 0x00 + 0xHH + 0xLL
The above data shows
⚫ Voltage is 0x0898, converted to decimal is 2200, display 220.0V
⚫ Current is 0x000003E8, converted to decimal is 1000, display 1.000A
⚫ Power is 0x00000898, converted to decimal is 2200, display 220.0W
⚫ Energy is 0x00000000, converted to decimal is 0, display 0Wh
⚫ Frequency is 0x01F4, converted to decimal is 500, display 50.0Hz
⚫ Power factor is 0x0064, converted to decimal is 100, display 1.00
⚫ Alarm status is 0x0000, indicates that the current power is lower than the alarm power
threshold
2.4 Read and modify the slave parameters
At present,it only supports reading and modifying slave address and power alarm threshold
The register is arranged as the following table
The command format of the master to read the slave parameters and read the measurement
results are same(descrybed in details in Section 2.3), only need to change the function code from
0x04 to 0x03.
The command format of the master to modify the slave parameters is (total of 8 bytes):
Slave Address + 0x06 + Register Address High Byte + Register Address Low Byte + Register
Value High Byte + Register Value Low Byte + CRC Check High Byte + CRC Check Low Byte.
The command format of the reply from the slave is divided into two kinds:
Correct Response: Slave Address + 0x06 + Number of Bytes + Register Address Low Byte +
Register Value High Byte + Register Value Low Byte + CRC Check High Byte + CRC Check Low
Byte.
Error Reply: Slave address + 0x86 + Abnormal code + CRC check high byte + CRC check
low byte.
For example, the master sets the slave's power alarm threshold:
0x01 + 0x06 + 0x00 + 0x01 + 0x08 + 0xFC + 0xHH + 0xLL
Indicates that the master needs to set the 0x0001 register (power alarm threshold) to 0x08FC
(2300W).
Set up correctly, the slave return to the data which is sent from the master.
For example, the master sets the address of the slave
0x01 + 0x06 + 0x00 + 0x02 + 0x00 + 0x05 + 0xHH + 0xLL
Indicates that the master needs to set the 0x0002 register (Modbus-RTU address) to 0x0005
Set up correctly, the slave return to the data which is sent from the master.
2.5 Reset energy
The command format of the master to reset the slave's energy is (total 4 bytes):
Slave address + 0x42 + CRC check high byte + CRC check low byte.
Correct reply: slave address + 0x42 + CRC check high byte + CRC check low byte.
Error Reply: Slave address + 0xC2 + Abnormal code + CRC check high byte + CRC check
low byte
2.6 Calibration
The command format of the master to calibrate the slave is (total 6 bytes):
0xF8 + 0x41 + 0x37 + 0x21 + CRC check high byte + CRC check low byte.
Correct reply: 0xF8 + 0x41 + 0x37 + 0x21 + CRC check high byte + CRC check low byte.
Error Reply: 0xF8 + 0xC1 + Abnormal code + CRC check high byte + CRC check low byte.
It should be noted that the calibration takes 3 to 4 seconds, after the master sends the
command, if the calibration is successful, it will take 3 ~ 4 seconds to receive the response from
the slave.
2.7 CRC check
CRC check use 16bits format, occupy two bytes, the generator polynomial is X16 + X15 +
X2 +1, the polynomial value used for calculation is 0xA001.
The value of the CRC check is a frame data divide all results of checking all the bytes except
the CRC check value.
3 Functional block diagram 
5 Other instructions
5.1The TTL interface of this module is a passive interface, it requires external 5V power supply, w
hich means, when communicating, all four ports must be connected (5V, RX, TX, GND), otherwis
e it cannot communicate.
5.2 Working temperature
-20’C ~ +60’C。

Specification

Brand Name : Ziqqucu

Operating Temperature : -20-+60

Type : Voltage Regulator

Dissipation Power : 0.4W

Model Number : PZEM-004T Digital Multifunction Meter

Supply Voltage : 80-260V

Application : Computer

Origin : CN(Origin)

Package : SOP

Condition : New

is_customized : Yes

PC923L SOP-8
USD 4.20
2-10pcs 6H02T BGA
USD 32.40USD 36.00
+